Your heat runs ten months a year here, September through June, and the overnight low averages 17°F in December, January and February. That's the question to answer before anything else, because a heat pump that can't hold the house warm on the coldest nights isn't a real option no matter what it costs to run.
A standard heat pump starts losing ground below 40°F. Below about 35°F it typically needs backup heat to keep up. Boulder County sees about 165 nights a year at or below freezing, over half the nights across the heating season, and every one of them falls below both marks. The average winter night here isn't an edge case for a standard heat pump. It's the normal case.
That doesn't rule out a heat pump, but it rules out a standard one running alone. The fix is a cold-climate model paired with backup heat for the coldest stretches, usually gas or electric resistance. A two-winter field test of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. That matters here because only about 7 nights a year drop to 0°F or below. The deep cold that would lean hardest on backup heat is rare. The ordinary cold, the kind in the 17°F to 32°F range, is what a cold-climate heat pump is built to handle on its own.
ENERGY STAR's Cold Climate listing sets the bar: at 5°F the unit has to still produce 1.75 units of heat per unit of electricity and hold onto at least 70 percent of its 47°F capacity. If you're looking at a heat pump for this county, that listing is what separates a unit that was tested for this cold from one that wasn't.