What the cold does to a heat pump here
Winter is the whole question in Alamosa County. The heat runs nine months a year, September through May, and the overnight low averages 8°F through December, January and February. That is not a cold snap. That is most nights, most of the winter.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says, and below about 35°F it often needs backup heat to keep up. Here, the average winter night is 8°F. Every one of the roughly 225 nights a year that drop to freezing or below is already past both of those marks. This is not a machine working near its edge once in a while. It is working past its edge most of the winter.
About 45 nights a year here hit 0°F or lower. That is under a quarter of the nights that freeze, but it tells you how deep the cold goes. A heat pump built to the federal minimum is not the machine rated for that. There is a version built for it: the ENERGY STAR Cold Climate heat pump, which has to prove it can still make 1.75 units of heat per unit of electricity at 5°F and hold on to 70 percent of its warm-weather capacity at that temperature, tested by a third party, not claimed by the manufacturer. In field tests of prototype cold-climate heat pumps over two winters, backup heat only carried a small share of the load between 0°F and 35°F, and the system rarely ran on backup alone even above 0°F. That is a different machine from the standard one the cost comparison above assumes. If a heat pump is on the table here, it is that version or nothing.